HANGZHOU HUATAI OPTIC TECH. CO., LTD
|
|
|
Product Classification |
|
|
|
PLC-2 × 口口口
Multi-wavelength Planar Lightwave Circuit Splitter (PLC Splitter) |
|
|
|
|
|
|
Technical index |
|
2 × 口口口optical splitter index :
Performance |
2x004 |
2x008 |
2x016 |
2x032 |
2x064 |
2x128 |
Fiber type |
G.657.A |
Working wavelength |
1260nm~1650nm |
Maximum insertiion loss uniformity(dB) |
≤ 7.6 |
≤ 11 |
≤ 14.8 |
≤ 17.5 |
≤ 20.6 |
≤ 23.7 |
Port insertion loss uniformity(dB) |
≤ 0.6 |
≤ 0.8 |
≤ 1.0 |
≤ 1.5 |
≤ 1.8 |
≤ 2.0 |
Port insertion loss uniformity(dB) |
≤ 0.8 |
≤ 0.8 |
≤ 1.0 |
≤ 1.0 |
≤ 1.0 |
≤ 1.2 |
Return loss(dB) |
≥55 |
≥55 |
≥55 |
≥55 |
≥55 |
≥55 |
Directivity(dB) |
≥55 |
≥55 |
≥55 |
≥55 |
≥55 |
≥55 |
Package type |
Bare fiber type |
50×7×4 |
50×7×4 |
60×12×4 |
60×12×4 |
80×12×6 |
- |
miniature type |
50×7×4 |
60×12×4 |
60×12×4 |
60×12×4 |
100×20×6 |
model type |
100×80×10 |
100×80×10 |
100×80×18 |
100×80×10 |
140×120×18 |
Blade package type |
130×100×25 |
130×100×25 |
30×100×50 |
130×100×100
or
260×100×50 |
130×100×200 |
Tray type |
288×180×25 |
288×180×25 |
288×180×25 |
288×180×50 |
288×180×100 |
Rack-mounted typed |
483×342×44 |
483×342×44 |
483×342×44 |
483×342×44 |
483×230×44 |
Note 1: The insertion loss with plug optical connector increase less than 0.3dB base on above requirements, other indexes are the same;
Note 2:The insertion loss of optical splitter with adapter(include 1U,Tray type and Blade package type) increase less than 0.2dB base on above requirements, other indexes are the same;
Note 3: The maximum insertion loss in 1260~1300,1600~1650nm wavelength range increase 0.3dB base on above requirements;
Note 4: Splitting ratio performance index of 128 is tentative;
Note 5:The working wavelength, insertion loss, return loss, directivity test method should according to Chapter Six of YD/T 1117-2001;
Note 6: The test method of Wavelength insertion loss uniformity as below: input end input 1260~1650nm broadband light source, output end switch in spectrum analyzer to measure the insertion loss that corresponding with wavelength, obtain the maximum and minimum of wavelength insertion loss. |
Working environment index
Performance |
Min. |
Type |
max |
Working temperature |
( ℃ ) |
-40 |
- |
+85 |
Wavelength insertion loss uniformity(dB) |
( ℃ ) |
-40 |
- |
+85 |
Return loss(dB) |
(Kpa) |
62 |
- |
106 |
Directivity(dB) |
(%) |
45 |
- |
75 |
Environmental performance requirements
No. |
Test item |
Test method |
Criterion |
Insertion loss variation |
Appearance change after test |
a |
High temperature |
85 ℃ (±2 ℃ ),duration time 96h,on-line test |
≤0.4 dB |
No mechanical damage in appearance, such as
deformation , cracks,
loose. No fiber fracture, fiber pull-out, fiber endpoint fault and cable seal damage etc. |
b |
Low temperature |
-40 ℃ (±2 ℃ ),duration time 96h,on-line test |
≤0.5 dB |
c |
dampness-heat |
75 ℃ (±2 ℃ ),95%(±5%)RH, duration time 96h,on-line test |
≤0.5 dB |
d |
Temperature cycling |
( -40 ℃ ~ + 85 ℃ ),one circulation 8h, 21 times circulation, on-line test |
≤0.5 dB |
e |
Water soaking |
Room temperature, tap-water, duration time 168h |
≤0.3 dB |
f |
Salt fog |
Saline solution: 5% NaCl, 6.5<PH<7.2;
Temperature : 35°C
duration time : 96 hours |
≤0.3 dB |
Note 1 : Temperature circulation test will be the conversion curve shown as below, one circulation takes 8h,21 times.
|
Mechanical performance index
No. |
Test item |
Test method |
Criterion |
Insertion loss variation |
Appearance change after test |
a |
Drop test |
Height:1.8m
Times:3 axial direction,each 8 times
Circulation:5 times |
≤0.4dB |
No mechanical damage in appearance,
such as deformation ,
cracks,
loose. No fiber fracture, fiber pull-out, fiber endpoint fault and cable seal damage etc. |
b |
Vibration test |
Frequency:10~55Hz
Scanning:45 time in a minute
Amplitude:0.75mm
Time:X,Y,Z direction each last 30min |
≤0.5dB |
c |
Optical cable Torsion test |
Load:
Φ2.0mm optical cable:15N
Φ0.9mm optical cable:4N
Φ0.25mm optical cable:2N
Method:load point 22~28cm away from the plug,
±1800
torsion,10 times/min,25 times |
≤0.4 dB |
d |
Optical cable tensile test |
Load:
Φ2.0mm optical cable:50N
Φ0.9mm optical cable:4N
Φ0.25mm optical cable:2N
Method:
Plug side :oad point 22 ~28cm away from the plug,2min;
Packaging side:load point 22~28cm away from the packaging point,2min; |
≤0.4 dB |
Note 1 : Optical cable tensile test include optical cable plug side test and packaging side test . |
Environmental lifetime index
No. |
Test item |
Test method |
Criterion |
Insertion loss variation |
Appearance change after test |
a |
High temperature storage(Dry) |
85 ℃ (±2 ℃ ),or highest storage temperature Humidity<40%RH,duration time 2000h |
≤0.5 dB |
No mechanical damage in appearance, such as
deformation, cracks,
loose. No fiber fracture, fiber pull-out, fiber endpoint fault and cable seal damage etc. |
b |
Low temperature cycling |
-40 ℃ (±5 ℃ ),or lowest st orage temperature,duration time 2000h |
≤0.5 dB |
c |
dampness-heat |
75 ℃ (±2 ℃ ),90%(±5%)RH, or 85 ℃ (±2 ℃ ),85%(±5%)RH,duration time 500h(COa);2000h(UNCb) |
≤0.5 dB |
d |
Temperature cycling |
( - 40 ℃ ~ +85 ℃ ),one circulation 8h ,500 times |
≤0.5 dB |
Note 1 : Temperature circulation test will be the conversion curve shown as below, one circulation takes 8h,500 times.
|
Order Explanation
|
|
|
|
|
|
|