HANGZHOU HUATAI OPTIC TECH. CO., LTD
 
Product Classification
PLC-2 × 口口口
Multi-wavelength Planar Lightwave Circuit Splitter (PLC Splitter)
  PLC-2 × 口口口 Product Photos Download Data Sheet
 
Technical index
 
2 × 口口口optical splitter index :
Performance 2x004 2x008 2x016 2x032 2x064 2x128
Fiber type G.657.A
Working wavelength 1260nm~1650nm
Maximum insertiion loss uniformity(dB) ≤ 7.6 ≤ 11 ≤ 14.8 ≤ 17.5 ≤ 20.6 ≤ 23.7
Port insertion loss uniformity(dB) ≤ 0.6 ≤ 0.8 ≤ 1.0 ≤ 1.5 ≤ 1.8 ≤ 2.0
Port insertion loss uniformity(dB) ≤ 0.8 ≤ 0.8 ≤ 1.0 ≤ 1.0 ≤ 1.0 ≤ 1.2
Return loss(dB) ≥55 ≥55 ≥55 ≥55 ≥55 ≥55
Directivity(dB) ≥55 ≥55 ≥55 ≥55 ≥55 ≥55
Package type Bare fiber type 50×7×4 50×7×4 60×12×4 60×12×4 80×12×6 -
miniature type 50×7×4 60×12×4 60×12×4 60×12×4 100×20×6
model type 100×80×10 100×80×10 100×80×18 100×80×10 140×120×18
Blade package type 130×100×25 130×100×25 30×100×50 130×100×100
or
260×100×50
130×100×200
Tray type 288×180×25 288×180×25 288×180×25 288×180×50 288×180×100
Rack-mounted typed 483×342×44 483×342×44 483×342×44 483×342×44 483×230×44
Note 1: The insertion loss with plug optical connector increase less than 0.3dB base on above requirements, other indexes are the same;
Note 2:The insertion loss of optical splitter with adapter(include 1U,Tray type and Blade package type) increase less than 0.2dB base on above requirements, other indexes are the same;
Note 3: The maximum insertion loss in 1260~1300,1600~1650nm wavelength range increase 0.3dB base on above requirements;
Note 4: Splitting ratio performance index of 128 is tentative;
Note 5:The working wavelength, insertion loss, return loss, directivity test method should according to Chapter Six of YD/T 1117-2001;
Note 6: The test method of Wavelength insertion loss uniformity as below: input end input 1260~1650nm broadband light source, output end switch in spectrum analyzer to measure the insertion loss that corresponding with wavelength, obtain the maximum and minimum of wavelength insertion loss.
Working environment index
Performance Min. Type max
Working temperature ( ℃ ) -40 - +85
Wavelength insertion loss uniformity(dB) ( ℃ ) -40 - +85
Return loss(dB) (Kpa) 62 - 106
Directivity(dB) (%) 45 - 75
Environmental performance requirements
No. Test item Test method Criterion
Insertion loss variation Appearance change after test
a High temperature 85 ℃ (±2 ℃ ),duration time 96h,on-line test ≤0.4 dB No mechanical damage in
appearance, such as
deformation , cracks,
loose. No fiber fracture,
fiber pull-out, fiber
endpoint fault and cable seal damage etc.
b Low temperature -40 ℃ (±2 ℃ ),duration time 96h,on-line test ≤0.5 dB
c dampness-heat 75 ℃ (±2 ℃ ),95%(±5%)RH, duration time 96h,on-line test ≤0.5 dB
d Temperature cycling ( -40 ℃ ~ + 85 ℃ ),one circulation 8h, 21 times circulation, on-line test ≤0.5 dB
e Water soaking Room temperature, tap-water, duration time 168h ≤0.3 dB
f Salt fog Saline solution: 5% NaCl, 6.5<PH<7.2;
Temperature : 35°C
duration time : 96 hours
≤0.3 dB
Note 1 : Temperature circulation test will be the conversion curve shown as below, one circulation takes 8h,21 times.

Mechanical performance index
No. Test item Test method Criterion
Insertion loss variation Appearance change after test
a Drop test Height:1.8m
Times:3 axial direction,each 8 times
Circulation:5 times
≤0.4dB No mechanical
damage in appearance,
such as deformation ,
cracks, loose. No fiber
fracture, fiber pull-out, fiber
endpoint fault and cable seal damage etc.
b Vibration test Frequency:10~55Hz
Scanning:45 time in a minute
Amplitude:0.75mm
Time:X,Y,Z direction each last 30min
≤0.5dB
c Optical cable Torsion test Load:
Φ2.0mm optical cable:15N
Φ0.9mm optical cable:4N
Φ0.25mm optical cable:2N
Method:load point 22~28cm away from the plug, ±1800 torsion,10 times/min,25 times
≤0.4 dB
d Optical cable tensile test Load:
Φ2.0mm optical cable:50N
Φ0.9mm optical cable:4N
Φ0.25mm optical cable:2N
Method: Plug side :oad point 22 ~28cm away from the plug,2min;
Packaging side:load point 22~28cm away from the packaging point,2min;
≤0.4 dB
Note 1 : Optical cable tensile test include optical cable plug side test and packaging side test .
Environmental lifetime index
No. Test item Test method Criterion
Insertion loss variation Appearance change after test
a High temperature storage(Dry) 85 ℃ (±2 ℃ ),or highest storage temperature Humidity<40%RH,duration time 2000h ≤0.5 dB No mechanical damage in
appearance, such as
deformation, cracks,
loose. No fiber fracture,
fiber pull-out, fiber
endpoint fault and cable seal damage etc.
b Low temperature cycling -40 ℃ (±5 ℃ ),or lowest st orage
temperature,duration time 2000h
≤0.5 dB
c dampness-heat 75 ℃ (±2 ℃ ),90%(±5%)RH, or 85 ℃ (±2 ℃ ),85%(±5%)RH,duration time 500h(COa);2000h(UNCb) ≤0.5 dB
d Temperature cycling ( - 40 ℃ ~ +85 ℃ ),one circulation 8h ,500 times ≤0.5 dB
Note 1 : Temperature circulation test will be the conversion curve shown as below, one circulation takes 8h,500 times.

Order Explanation

Copyright © 2006-2007 Hangzhou Huatai Optic Tech Co., Ltd. All rights reserved.
Zhejiang ICP keep on record: 05003023