 PON Module
PON Model |
HOPM-3213 |
HOPM-3213A |
HOPM-3213AV |
HOPM-3213AP |
1310nm upstream measurement |
Pass zone |
(nm) |
1260~1360 |
Measurement range |
(dBm) |
-40~+10 |
Output power (max) |
(dBm) |
15 |
Isolation@1490/1550 |
(dB) |
>40 |
Burst mode measurement error |
(dB) |
<±0.5 |
1490 downstream measurement |
Pass zone |
(nm) |
1470~1505 |
Measurement range |
(dBm) |
-40~+10 |
Output power (max) |
(dBm) |
15 |
Isolation@1310/1550 |
(dB) |
>40 |
1550 downstream measurement |
Pass zone |
(nm) |
1535~1570 |
Measurement range |
(dBm) |
-40~+10 |
Output power (max) |
(dBm) |
25 |
Isolation@1310/1490 |
(dB) |
>40 |
Measurement accuracy |
Connatural uncertainty |
(dB) |
±0.5 |
Linearity |
(dB) |
±0.1 |
Passing through insertion loss |
(dB) |
<1.5 |
General information |
Detector type |
|
InGaAs |
Optical connector |
|
FC/SC/ST Interchangeable/2.5 universal adapter |
Fiber type |
|
SM 9/125um |
Measurement unit |
|
dB/dBm/xW |
Resolution |
(dB) |
0.01 |
Operation voltage |
(V) |
DC 3.3V~5.5V |
Power supply |
|
3pc1.5V battery |
Continuously operation time |
|
PON:90h |
PON:90h
OPM:100h
VFL:50h |
PON:90h
VFL:50h |
PON:90h
OPM:100h |
Operation Temperature |
(℃) |
-10~60 |
Storge temperature |
(℃) |
-25~70 |
Weight |
(g) |
423 |
425 |
424 |
424 |
Note: The operation time of the battery are all for the instrument that do not turn on backlight, if the backlight turn on the operation time will be shorted.
 Normal Optical Power Meter Module:
Normal Model |
HOPM-32131) |
HOPM-3213A |
HOPM-3213AP |
1310nm upstream measurement |
Connatural uncertionty |
(dB) |
None |
±0.5 |
Liearity |
(dB) |
±0.1 |
Measurement range |
(dBm) |
-70~+6 |
General Information
|
Measurement unit |
|
None |
dB/dBm |
Resolution |
(dB) |
0.01 |
Calibration wavelength |
(nm) |
1300/1310/ 1490/1550/1625 |
850/1300/1310/ 1490/1550/1625 |
Detector type |
|
InGaAs |
Optical connector |
|
FC/SC/ST Interchangeable/2.5 universal adapter |
1): PON Optical Power Meter do not have the OPM module
 VFL Module:
Normal Model |
HOPM-32131) |
HOPM-3213A |
HOPM-3213AP |
Output power |
(mW) |
None |
±0.5 |
Wavelength |
(nm) |
±0.1 |
Optical connector |
|
FC/SC/ST Interchangeable/2.5 universal adapter |
Fiber type |
|
SM/MM |
1):PON Optical Power Meter without VFL module.
|