Performance |
Index |
Supplement |
Min. |
typ. |
Max. |
Optical feature |
Laser type |
A type |
|
Cooling DFB |
A1310, A1550, A15口口 |
B type |
Non-cooling DFB with optical isolation |
B1310, B1550 |
Operating Wavelength |
(nm) |
1300 |
1310 |
1320 |
A1310, B1310 |
1530 |
1550 |
1563 |
A1550, B1550 |
|
ITU-G |
|
A15口口 |
1270 |
CWDM |
1610 |
B1口口口 |
Wavelength adjustable range |
(nm) |
-1.6 |
|
+1.6 |
A15口口 |
Wavelength adjustable mode |
|
In steps ±0.01nm |
A15口口 |
Wavelength stability |
(Pm/℃) |
-1 |
|
0 |
TC=20~70℃ |
Equivalent noise temperature |
(dB/Hz) |
|
|
-155 |
|
Side mode suppression ratio |
(dB) |
35 |
|
|
|
Optical isolation |
(dB) |
30 |
|
|
|
Extinction ratio |
(dB) |
8.2 |
|
|
|
SBS |
(dBm) |
16
|
|
|
1310nm |
18
|
|
|
1550nm |
Optical output power |
(mW) |
1 |
|
10 |
B1310 |
10 |
|
30 |
A1310 |
1.0 |
|
4 |
B1550, B1口口口 |
4 |
|
10 |
A1550, A15口口 |
Return loss |
(dB) |
50
|
|
|
|
Optical connector |
|
SC/APC & LC/APC |
|
RF
feature |
Operating bandwidth |
(MHz) |
950 |
|
2600 |
|
Input range |
(dBm) |
-40 |
|
-25 |
TX, SAT-IF with AGC amplification |
|
-8 |
|
TX, SAT-IF without IF amplification |
Flatness |
(dB) |
|
0.5 |
|
40MHz |
-2.0 |
|
+2.0 |
950~2400MHz |
Return loss |
(dB) |
10 |
|
|
950~2400MHz |
Input ompendance |
( Ω ) |
75 |
|
|
|
CNR |
(dB) |
28 |
|
|
|
CTB |
(dB) |
|
|
-36 |
|
CSO |
(dB) |
|
|
-36 |
|
To LNB voltage |
(V) |
|
13/18 |
|
|
To LNB current |
(mA) |
|
|
300 |
|
General featre |
SNMP interface |
|
RJ45 |
HDS-26S-1-口口 |
Communication interface |
|
RS232 |
HDS-26S-1-口口 |
Power supply |
AC |
(V) |
90
|
220 |
265 |
|
DC |
-30 |
-48 |
-72 |
|
Power consumption |
(W) |
|
|
5 |
Single PS |
Operating temp. |
(℃) |
-5 |
|
+65 |
|
Storage temp. |
(℃) |
-40 |
|
+85 |
|
Relative humidity |
(%) |
5 |
|
95 |
|
Size |
|
19×14.5×1.75 ( " )
483×368×44 ( mm ) |
HDS-26S-1-口口 |
2.3×3.9×0.9 ( " )
59×98×23 ( mm ) |
HDS-26S-2-口口 |
4.6×2.8×1.1 ( " )
117×72×29 ( mm ) |
HDS-26S-3-口口 |
5.9×5.3×3.9 ( " )
150×135×98 ( mm ) |
HDS-26S-9-口口 |
Link performance
Optical input (dB) |
Link loss (dB) |
CNR (dB) |
Link gain (dB) |
RF output level (dBm/Ch.) |
-13 |
14 |
30.18 |
-2 |
-38 |
-12 |
13 |
32.18 |
0 |
-36 |
-11 |
12 |
34.13 |
2 |
-34 |
-10 |
11 |
38.59 |
6 |
-32 |
-8 |
9 |
40.11 |
8 |
-30 |
-7 |
8 |
42.18 |
10 |
-28 |
-6 |
7 |
44.24 |
12 |
-26 |
-5 |
6 |
45.67 |
14 |
-24 |
-4 |
5 |
46.53 |
16 |
-22 |
-3 |
4 |
46.76 |
18 |
-20 |
-2 |
3 |
46.92 |
20 |
-18 |
-1 |
2 |
47.01 |
22 |
-16 |
0 |
1 |
47.03 |
24 |
-14 |
Remarks: 1. General input level of digital satellite receiver: -60dBm ~ -30dBm.
2. TX Output=1dBm.
3. RX adopt HRS26S/P.
Product series
HDS-26S-1-口口 ( 19" Stander type )
Mode |
Wavelength |
Output power |
Exterior |
Connector |
HDS-26S-1-10-TG/A1310-SA |
1310nm
Cooling DFB |
10mW |
19" Stander type |
SC/APC |
HDS-26S-1-12-TG/A1310-SA |
12mW |
SC/APC |
HDS-26S-1-14-TG/A1310-SA |
14mW |
SC/APC |
HDS-26S-1-16-TG/A1310-SA |
16mW |
SC/APC |
HDS-26S-1-18-TG/A1310-SA |
18mW |
SC/APC |
HDS-26S-1-20-TG/A1310-SA |
20mW |
SC/APC |
HDS-26S-1-24-TG/A1310-SA |
24mW |
SC/APC |
HDS-26S-1-30-TG/A1310-SA |
30mW |
SC/APC |
HDS-26S-1-01-TG/B1310-SA |
1310nm
Non-cooling DFB |
1mW |
19" Stander type |
SC/APC |
HDS-26S-1-02-TG/B1310-SA |
2mW |
SC/APC |
HDS-26S-1-03-TG/B1310-SA |
3mW |
SC/APC |
HDS-26S-1-04-TG/B1310-SA |
4mW |
SC/APC |
HDS-26S-1-06-TG/B1310-SA |
6mW |
SC/APC |
HDS-26S-1-08-TG/B1310-SA |
8mW |
SC/APC |
HDS-26S-1-10-TG/B1310-SA |
10mW |
SC/APC |
HDS-26S-1-04-TG/A1550-SA |
1550nm
Cooling DFB |
4mW |
19" Stander type |
SC/APC |
HDS-26S-1-06-TG/A1550-SA |
6mW |
SC/APC |
HDS-26S-1-08-TG/A1550-SA |
8mW |
SC/APC |
HDS-26S-1-10-TG/A1550-SA |
10mW |
SC/APC |
HDS-26S-1-01-TG/B1550-SA |
1550nm
Non-cooling DFB |
1mW |
19" Stander type |
SC/APC |
HDS-26S-1-02-TG/B1550-SA |
2mW |
SC/APC |
HDS-26S-1-03-TG/B1550-SA |
3mW |
SC/APC |
HDS-26S-1-04-TG/B1550-SA |
4mW |
SC/APC |
Remarks: 1. Two type optional, without IF drive amplify.
2. ITU standard wavelength adjustable in 1550nm.
3. CWDM working wavelength optional.
HDS-26S-2-口口 ( Desktop type )
Mode |
Wavelength |
Output power |
Exterior |
Connector |
HDS-26S-2-01-TG/B1310-SA |
1310nm
Non-cooling DFB |
1mW |
Desktop type |
SC/APC |
HDS-26S-2-02-TG/B1310-SA |
2mW |
SC/APC |
HDS-26S-2-03-TG/B1310-SA |
3mW |
SC/APC |
HDS-26S-2-04-TG/B1310-SA |
4mW |
SC/APC |
HDS-26S-2-06-TG/B1310-SA |
6mW |
SC/APC |
HDS-26S-2-08-TG/B1310-SA |
8mW |
SC/APC |
HDS-26S-2-10-TG/B1310-SA |
10mW |
SC/APC |
HDS-26S-2-01-TG/B1550-SA |
1550nm Non-cooling DFB |
1mW |
Desktop type |
SC/APC |
HDS-26S-2-02-TG/B1550-SA |
2mW |
SC/APC |
HDS-26S-2-03-TG/B1550-SA |
3mW |
SC/APC |
HDS-26S-2-04-TG/B1550-SA |
4mW |
SC/APC |
Remarks: 1. Two type optional, without IF drive amplify.
2. CWDM working wavelength optional.
HDS-26S-3-口口 ( Wall-mounted type )
Mode |
Wavelength |
Output power |
Exterior |
Connector |
HDS-26S-3-01-TG/B1310-SA |
1310nm
Non-cooling DFB |
1mW |
Wall-mounted type |
SC/APC |
HDS-26S-3-02-TG/B1310-SA |
2mW |
SC/APC |
HDS-26S-3-03-TG/B1310-SA |
3mW |
SC/APC |
HDS-26S-3-04-TG/B1310-SA |
4mW |
SC/APC |
HDS-26S-3-06-TG/B1310-SA |
6mW |
SC/APC |
HDS-26S-3-08-TG/B1310-SA |
8mW |
SC/APC |
HDS-26S-3-10-TG/B1310-SA |
10mW |
SC/APC |
HDS-26S-3-01-TG/B1550-SA |
1550nm Non-cooling DFB |
1mW |
Wall-mounted type |
SC/APC |
HDS-26S-3-02-TG/B1550-SA |
2mW |
SC/APC |
HDS-26S-3-03-TG/B1550-SA |
3mW |
SC/APC |
HDS-26S-3-04-TG/B1550-SA |
4mW |
SC/APC |
Remarks: 1. Two type optional, without IF drive amplify.
2. CWDM working wavelength optional.
HDS-26S-9-口口 ( Outdoor rain-proof type )
Mode |
Wavelength |
Output power |
Exterior |
Connector |
HDS-26S-9-01-TG/B1310-SA |
1310nm
Non-cooling DFB |
1mW |
Outdoor rain-proof type |
SC/APC |
HDS-26S-9-02-TG/B1310-SA |
2mW |
SC/APC |
HDS-26S-9-03-TG/B1310-SA |
3mW |
SC/APC |
HDS-26S-9-04-TG/B1310-SA |
4mW |
SC/APC |
HDS-26S-9-06-TG/B1310-SA |
6mW |
SC/APC |
HDS-26S-9-08-TG/B1310-SA |
8mW |
SC/APC |
HDS-26S-9-10-TG/B1310-SA |
10mW |
SC/APC |
HDS-26S-9-01-TG/B1550-SA |
1550nm Non-cooling DFB |
1mW |
Outdoor rain-proof type |
SC/APC |
HDS-26S-9-02-TG/B1550-SA |
2mW |
SC/APC |
HDS-26S-9-03-TG/B1550-SA |
3mW |
SC/APC |
HDS-26S-9-04-TG/B1550-SA |
4mW |
SC/APC |
Remarks: 1. Two type optional, without IF drive amplify.
2. CWDM working wavelength optional.
|